DW808DP-R differential pressure remote transmitter is used to measure the level, density, pressure and flow of liquid, gas or steam, and then convert them into 4 ~ 20mADCHart current signal output. DW808DP-R can also communicate with RST375 handheld terminal or DWM100 Modem, through which parameter setting, process monitoring and so on can be carried out. The measurement range of DW808DP-R differential pressure remote transmitter (without transfer) is 0-1kPa ~ 2MPa, and the rated pressure of remote flange is 1.6/4MPa, 6.4MPa, 10MPa, 150psi, 300psi or 600psi respectively.
The DW808DP-R differential pressure remote transmitter is used to measure the liquid level, density, pressure, and flow rate of liquids, gases, or steam, and then converts them into 4~20mADCHART current signals for output. The DW808DP-R can also communicate with the RST375 handheld terminal or DWM100 Modem for parameter setting, process monitoring, and other purposes.
The measurement range of the DW808DP-R differential pressure remote transmitter (before migration) is 0-1kPa to 2MPa, and the rated pressures of the remote flanges are respectively: 1.6/4MPa, 6.4MPa, 10MPa, 150psi, 300psi, or 600psi.
Product Features
The capsule of this differential pressure remote transmitter is used to prevent the medium in the pipeline from directly entering the pressure sensor assembly of the differential pressure transmitter. It transfers pressure with the transmitter through a filling liquid such as silicone oil
Multiple debugging methods; local buttons, handheld operator, communication software
Output communication protocol: HART
Protection level: IP67
A variety of anti-corrosion materials are available to meet the needs of various working conditions.
The watch case can rotate 360° and can be installed and fixed in any position.
Technical Specifications
Environmental temperature: -40℃~+85℃ (the lowest depends on the filling liquid)
(With LCD display, filled with fluorinated oil: -20℃~+65℃)
Temperature influence: within the range of -20℃ to +65℃:
±(0.1URL+0.1%Span)/10℃
Relative humidity: 0-100%
Medium temperature: -30~400℃
Long-term drift: ±0.1% of URL per year
Output communication protocol: HART
Output function: Linear
Enclosure protection level: IP67
Filling fluid: silicone oil, fluorinated oil, etc
Isolation diaphragm material: 316L, Hastelloy C, etc
Output functions: linear, square root, etc